Zephyr BVE-E36AS Przewodnik Instalacji

Przeglądaj online lub pobierz Przewodnik Instalacji dla Okapy kuchenne Zephyr BVE-E36AS. Zephyr BVE-E36AS Installation guide [en] [es] [fr] Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - VCA-E30AW

Use, Care, and Installation GuideModel number: Serial Number: DEC11.0101CascadeVCA-E30ASVCA-E30ABVCA-E30AW

Strona 2

8Installation – Specifi cationselec.k/oTOP6” Round DuctingBACKSIDE27 13/16”2”8 5/8”12 3/16”3/4”4 3/16”6”10”2 3/4”5 7/8”5 7/8”7/8”elec.k/o10”3 1/4”11/16

Strona 3

9ELECTRICALWARNINGAll Electrical work must by performed by qualifi ed electrician or person with similar technical know how and background.For personal

Strona 4

1. Remove filters2. Remove cover from junction box to gain access to electrical wiring.3. If using a cable lock, pry open the desired electrical kno

Strona 5

An air recirculating kit (optional) must be purchased before using hood in recirculat-ing mode.1. Secure each of the (2) spring clips to the safety g

Strona 6

Installation – Converting to Air Recirculating Mode125. Remove each of the 5 screws holding the (2) interior recirculating panels.6. Remove (2) inte

Strona 7

13For Mounting Under a Kitchen Cabinet (Fig 1)1. Select preferred duct location (vertical or horizontal) if ducting air out of kitchen. Refer to page

Strona 8

14Features & Controls – Rocker ControlsThis switch turns the blower on and o and controls the speed selection.is o, is low speed andis high spee

Strona 9

15SURFACE MAINTENANCE:Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouri

Strona 10 - Installation – Specifi cations

16REPLACING LIGHT BULBSCAUTION: Light bulb becomes extremely hot when turned on.DO NOT touch bulb until switched off and cooled. Touching hot bulbs c

Strona 11 - ELECTRICAL

Troubleshooting17TROUBLESHOOTING PROCEDURES FOR CASCADEIssue Cause What to doAfter installation, the unit doesn’t work.1. The power source is not tur

Strona 13

Wiring Diagrams18

Strona 14

19DESCRIPTION PART # Replacement PartsLight Bulb, MR16 GU10, 35W (each) Z0B0023

Strona 15

Use, Care, and Installation GuideModel number: Serial Number: DEC11.0101CascadeVCA-E30ASVCA-E30ABVCA-E30AW

Strona 17 - SURFACE MAINTENANCE:

1SAFETY NOTICE ... 2-3LIST OF MATERIALS ...

Strona 18 - Maintenance – Lights

Important Safety NoticeREAD AND SAVE THESE INSTRUCTIONS2WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE

Strona 19 - Troubleshooting

Important Safety Notice3WARNINGTO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.NOT FOR USE OVER AN OUTDOOR GRILL.CAUTIONTo reduce risk of fi re and

Strona 20 - Wiring Diagrams

List of Materials4MODELS: VCA-E30AS, VCA-E30AB, VCA-E30AWPARTS SUPPLIED1 - Hood2 - Aluminum Mesh Filters2 - Halogen Light Bulbs (GU10, 35W)1 - 6” Roun

Strona 21 - List of Parts and Accessories

5Installation – Ducting Calculation SheetDuct piecesTo t a lEquivalent numberlength x used =3-1/ 4” x 10”Rect.,straight1 Ft. x ( ) =

Strona 22

Installation – Mounting Height & Clearance6DUCTINGA minimum 6” round or 3-1/4” x 10” rectangular duct must be used to maintain maximum air fl ow ef

Strona 23

1SAFETY NOTICE ... 2-3LIST OF MATERIALS ...

Strona 24 - Table of Contents

7WARNING FIRE HAZARDNEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be

Strona 25 - Important Safety Notice

8Installation – Specifi cationselec.k/oTOP6” Round DuctingBACKSIDE27 13/16”2”8 5/8”12 3/16”3/4”4 3/16”6”10”2 3/4”5 7/8”5 7/8”7/8”elec.k/o10”3 1/4”11/16

Strona 26

9ELECTRICALWARNINGAll Electrical work must by performed by qualifi ed electrician or person with similar technical know how and background.For personal

Strona 27 - List of Materials

1. Remove filters2. Remove cover from junction box to gain access to electrical wiring.3. If using a cable lock, pry open the desired electrical kno

Strona 28 - Total ductwork =

An air recirculating kit (optional) must be purchased before using hood in recirculat-ing mode.1. Secure each of the (2) spring clips to the safety g

Strona 29 - Min 24” - Max 32"

Installation – Converting to Air Recirculating Mode125. Remove each of the 5 screws holding the (2) interior recirculating panels.6. Remove (2) inte

Strona 30 - WARNING FIRE HAZARD

13For Mounting Under a Kitchen Cabinet (Fig 1)1. Select preferred duct location (vertical or horizontal) if ducting air out of kitchen. Refer to page

Strona 31

14Features & Controls – Rocker ControlsThis switch turns the blower on and o and controls the speed selection.is o, is low speed andis high spee

Strona 32

15SURFACE MAINTENANCE:Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouri

Strona 33

16REPLACING LIGHT BULBSCAUTION: Light bulb becomes extremely hot when turned on.DO NOT touch bulb until switched off and cooled. Touching hot bulbs c

Strona 34

Important Safety NoticeREAD AND SAVE THESE INSTRUCTIONS2WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE

Strona 35

Troubleshooting17TROUBLESHOOTING PROCEDURES FOR CASCADEIssue Cause What to doAfter installation, the unit doesn’t work.1. The power source is not tur

Strona 36

Wiring Diagrams18

Strona 37

19DESCRIPTION PART # Replacement PartsLight Bulb, MR16 GU10, 35W (each) Z0B0023

Strona 38

1-888-880-8368STAPLE YOUR RECEIPT HERETO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: Zephyr Corporation (refe

Strona 39

1-888-750-1698STAPLE YOUR RECEIPT HERETO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: Valore (referred to here

Strona 40

Guide d’utilisation, d’entretien et d’installationNuméro de modèle Numéro de série: DEC11.0101CascadeVCA-E30ASVCA-E30ABVCA-E30AW

Strona 42

1MISE EN GARDE DE SÉCURITÉ ... 2-3LISTE DU MATÉRIEL ... 4INSTALLATIONFeuil

Strona 43 - Limited Warranty

Mise en garde de sécuritéLISEZ ET CONSERVEZ CES INSTRUCTIONS2AVERTISSEMENTPOUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PA

Strona 44

Mise en garde de sécurité3ATTENTIONPOUR RÉDUIRE LES RISQUES D’INCENDIE, N’UTILISEZ QUE DES CONDUITS D’AÉRATION EN MÉTAL.CET APPAREIL N’EST PAS CONÇU P

Strona 45

Important Safety Notice3WARNINGTO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.NOT FOR USE OVER AN OUTDOOR GRILL.CAUTIONTo reduce risk of fi re and

Strona 46

Liste du matériel4MODÈLES : VCA-E30AS, VCA-E30AB, VCA-E30AWPIÈCES FOURNIES1 - Hotte2 - Filtre à tamis en aluminium2 - Ampoules halogènes (GU-10 35W)1

Strona 47 - Table des Matières

5Installation – Feuille de calcul pour le conduit d’aérationPièces de conduitTotalLongueur x Nombre utilisé 3-1/ 4” x 10”rect., droit1 pi x

Strona 48 - Mise en garde de sécurité

Installation – Espace libre et hauteur de montage6CONDUIT D’AÉRATIONUn conduit circulaire de 6” ou rectangulaire de 3¼” x 10” doit être utilisé pour

Strona 49

7AVERTISSEMENT DE RISQUE D’INCENDIEN’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le

Strona 50 - Liste du matériel

8Installation – Entréedéfonçablepour élec.HAUTConduit circ. de 6"ARRIÈRECÔTÉ27 13/16”2”8 5/8”12 3/16”3/4”4 3/16”6”10”2 3/4”5 7/8”5 7

Strona 51 - Total du conduit =

9ÉLECTRICITÉAVERTISSEMENTl’expérience technique et

Strona 52 - CONDUIT D’AÉRATION

1. Enlevez les filtres. 2. Enlevez le couvercle de la boîte de connexion pour avoir accès au câblage électrique.3. Si vous utilisez un raccord de câ

Strona 53 - Bouche d’aération de

Vous devez vous procurer un ensemble de recirculation d’air (optionnel) avant d’utiliser la hotte en mode de recirculation d’air.1. Fixez les deux at

Strona 54 - Installation – 

Installation – Utilisation du mode de recirculation d’air 125. Enlevez les cinq (5) vis qui retiennent les deux (2) panneaux intérieurs de recirculat

Strona 55 - AVERTISSEMENT

13Pour une installation sous une armoire de cuisine (Fig. 1)1. Déterminez l’emplacement désiré du conduit (vertical ou horizontal) si vous évacuez l’

Strona 56

List of Materials4MODELS: VCA-E30AS, VCA-E30AB, VCA-E30AWPARTS SUPPLIED1 - Hood2 - Aluminum Mesh Filters2 - Halogen Light Bulbs (GU10, 35W)1 - 6” Roun

Strona 57

14Commandes – Commandes à bascule0 0Allumer/Éteindre – Choix de vitesse Lumières : Éteintes/Veilleuse/AlluméesAllumer/Éteindre – Choix de vitesse Cet

Strona 58

15ENTRETIEN DES SURFACESNettoyez régulièrement les surfaces de la hotte avec de l’eau savonneuse chaude et un chiffon de coton propre. N’utilisez pas

Strona 59 - Électricité

16REMPLACEMENT DES AMPOULESATTENTION : Les ampoules deviennent extrêmement chaudes lorsqu’allumées.Veuillez NE PAS les toucher avant de les avoir étei

Strona 60

Dépannage 17PROCÉDURES DE DÉPANNAGE POUR LA HOTTE CASCADEProblème Cause SolutionAprès l’installation, l’appareil ne fonctionne pas.1. Le bloc d’alime

Strona 61 - ENTRETIEN DES SURFACES

Entretien - Schéma de câblage186FKËPDGHFLUFXLWVModèleTensionConsommation d’énergieLampe : Ventilateur :PROTÉGÉ THERMIQUEMENT5HPDUTXHV&RQGHQVDWH

Strona 62 - Entretien – Lumières

19DESCRIPTION Nº DE PIÈCEPièces de remplacementAmpoule MR16 GU10, 35W (chaque) Z0B0023

Strona 63 - Dépannage

AGRAFEZ VOTRE REÇU ICIPOUR OBTENIR DU SERVICE SOUS GARANTIE OU POUR TOUTE QUESTION LIÉE À L’ENTRETIEN, veuillez communiquer avec nous au 1-888-750-169

Strona 64 - Entretien - Schéma de câblage

5Installation – Ducting Calculation SheetDuct piecesTo t a lEquivalent numberlength x used =3-1/ 4” x 10”Rect.,straight1 Ft. x ( ) =

Strona 65

Installation – Mounting Height & Clearance6DUCTINGA minimum 6” round or 3-1/4” x 10” rectangular duct must be used to maintain maximum air fl ow ef

Strona 66 - Garantie limitée

7WARNING FIRE HAZARDNEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be

Komentarze do niniejszej Instrukcji

Brak uwag